Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Certificat
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
Je suis en ligne une discussion en ligne

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ
Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Image Grand :  Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: Kingway
Certification: CE/ISO
Numéro de modèle: KL500
Conditions de paiement et expédition:
Quantité de commande min: 1 unité
Prix: USD9900-15000/Unit
Détails d'emballage: Cas de contreplaqué
Délai de livraison: 60 jours
Conditions de paiement: LC, T/T
Capacité d'approvisionnement: 100 unités par 60 jours

Heavy-Duty Resistive Load Bank Forced-Air Cooling 500kW Capacity 400V 50/60HZ

description de
Mettre en évidence:

Heavy-duty resistive load bank 500kW

,

Forced-air cooling load bank 400V

,

Resistive load bank 50/60Hz

Technical Specifications
Rated Power 500KW
Rated Voltage 400V
Load Step Respectively: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200 KW
Frequency 50/60HZ
Insulation Class F Class
Key Features
High-Quality Resistors Alloy Resistors
Cooling System Forced-air Cooling
Control Modes Local Manual Control or RS232/RS485
Safety Protection
Over-temperature Alarm Automatic unload and alarm when temperature is over
safety thresholds
Fan Failure Protection Machine could not load testing before power of fan is
power on
Emergency Stop User can press emergency stop button in panel to unload
immediately when load bank is abnornal while working
Short Circuit Protection The load circuit is equipped with a fuse to avoid damage
to the equipment by short-circuiting the load or excessive
current
Applications
Generator Set Testing Prevent "Wet Stacking" and perform full-load exercises
UPS & Battery Bank
Maintenance
Periodic discharge testing to verify actual capacity
Data Center Acceptance Simulate server heat and electrical loads for
comprehensive commissioning
R&D/Laboratory For performance burn-in and stress testing of power
electronics