Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Certificat
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
Je suis en ligne une discussion en ligne

Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning
Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Image Grand :  Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: King
Certification: CE/ISO
Numéro de modèle: KL20
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: USD1250-1500/Unit
Détails d'emballage: Cas de contreplaqué
Délai de livraison: 60 jours
Conditions de paiement: LC, T/T
Capacité d'approvisionnement: 100 unités par 60 jours

Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

description de

Technical Specifications
Rated Voltage & Frequency AC Single-phase, AC240V 60Hz
Rated Power Resistive Load: 20kW @ 240V/60Hz
Power Factor 1
Load Step o Respectively:
o Channel A: FAN, 1kW, 1kW;
o Channel B: 3kW;
o Channel C: 3kW;
o Channel D: 3kW;
o Channel E: 3kW;
o Channel F: 3kW;
o Channel H: 3kW.
o Note: 1. Step power is the nominal power at 240V, excluding fan power; 2. When the input voltage is lower than
the rated voltage, the power is calculated according to Ohm's Law.
Interface Description 1. Chassis rear panel; Input interface is a 3-core power socket (C20); Testing cable load end connector is C19;
2. The load utilizes a manual control method, equipped with 9 miniature circuit breakers (MCBs), of which 1 controls the fan and 8 control the load steps.
3. The 7 input ports can be arbitrarily connected to different power sources; if Channel A loses power, the load will not work.
Insulation Class F Class
Load Step Accuracy ±5%
Full Load Accuracy ±3%
Wiring Method 3-core power socket (C20); Wiring Location: Chassis real panel
Protection Level IP20
Chassis Color Black
Operation Mode Continuous operation
Handling Method Can be carried using the front panel insatallation handles, equipped
with mounting ears
Main Component Brands
Step Switches Schneider
Low Voltage Contactors Schneider
Power Unit Material Nickel-Chromium Alloy
Key Features
High-Quality Resistors Alloy Resistors
Cooling System Forced-air Cooling, front air intake, rear air exhaust
Control Modes Local Manual Control or RS232/RS485
Safety Protection
Over-temperature Alarm Automatic unload and alarm when temperature is over
safety thresholds
Fan Failure Protection Machine could not load testing before power of fan is
power on
Emergency Stop User can press emergency stop button in panel to unload
immediately when load bank is abnornal while working
Short Circuit Protection The load circuit is equipped with a fuse to avoid damage
to the equipment by short-circuiting the load or excessive
current
Applications
Generator Set Testing Prevent "Wet Stacking" and perform full-load exercises
UPS & Battery Bank
Maintenance
Periodic discharge testing to verify actual capacity
Data Center Acceptance Simulate server heat and electrical loads for
comprehensive commissioning
R&D/Laboratory For performance burn-in and stress testing of power
electronics
Product Informaiton
Product Size 431x444.50x500mm
Product Weight 32 Kgs
Operating Environment Parameters
Operating Temperature -10°C to +40°C
Storage Environment -15°C to +50°C; 20%RH to 90%RH
Altitude <1500 meters
Atmospheric Pressure 86~106kPa

 

Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning 0