logo
  • French
Aperçu ProduitsBanque de charge résistive

Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank

Certificat
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
LA CHINE Qingdao Kingway Industry Co., Ltd. certifications
Je suis en ligne une discussion en ligne

Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank

Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank
Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank

Image Grand :  Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank

Détails sur le produit:
Lieu d'origine: Shandong, Chine
Nom de marque: Kingway
Numéro de modèle: KL-100
Conditions de paiement et expédition:
Prix: $9,500.00/units

Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank

description de
Voltage nominal: Pour les appareils électriques Vitesse: Pour les véhicules à moteur à combustion
Fréquence: 50 Hz Système de démarrage: Télélancement
Le type: type portatif Type de système de refroidissement: Système de ventilation
Facteur de puissance: 1.0 Charge résistive: 10 étapes
Puissance résistive: 100 kW/100kva Le pouvoir apparent: 100 kW
Interface de communication: RS232/RS485 Contacteur: - Je ne sais pas.
le fusible: MIRO PLC: Les scientifiques
Résistant allié: Je suis désolé. Logiciel informatique: Je suis désolé.
Garantie: 12 mois

 

Testing diesel generator 400v 50hz 3 Phasse 4 Wire 100kw resistive load bank 0100 kw Resistive Load Bank for Generator Testing

Lead times are currently less than 3 months!

Three-phase model options range from small, portable, low-power units, to high-power, indoor & outdoor permanent resistive load banks. Models come standard with push-button manual controls as well as PC software controls offering advanced load profile solutions for working with complex testing applications.  Units are suitable for various uses including testing of generators, UPS systems, data center power systems, power supplies, HVAC systems, and other critical power sources. Single-phase load bank models also available.

Design elements incorporate a robust steel outer chassis with isolated interior chambers for control and load elements. This ensures electrical components are kept away from dirt and debris for long-life reliability in harsh test environments. Portable options include lifting eyes and caster wheels while permanent and outdoor rated units are available. All resistive load banks come with multiple built-in automatic safety shutdowns and manual override shutdown.

Benefits

  • Digital metering for high-precision data read-out
  • User controlled manually or through software with programmed load profile
  • Detailed data management, analysis, and report generation through software
  • Automatic load testing allows user to set custom periods of power and time
  • Display of current, voltage, power, power factor, frequency, and time
  • Emergency manual stop button for quick termination of load test
  • Automatic stop protection for adverse conditions including over-load, over-voltage, high temperature, short-circuit
  • Optional serial RS-485 Modbus controls
  • Optional dry contact terminal controls
  • Optional outdoor rated enclosures (available on models over 100kw)
  • Load Bank FAQ

    1. What is a load bank?


    A load bank is a device designed to provide electrical loads for testing various power sources, Including Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators etc.


    2. Why is Load Testing Important?
    Load bank testing will save your time and money in the long run. It is how you determine the operating status of your primary power systems. It's also how you exercise backup systems to ensure they will be available when called upon. Load testing at start-up and during commissioning and maintenance will detect problematic conditions before they escalate and cause downtime.

     

    3. What are the different types of load banks?
    Resistive, Inductive, capacitive and Resistive/Inductive combined

     

    4. Can the Load Bank test at single phase?
    Yes, but the rating available is 1/6 of the rated testing capacity.

     

    5. Is it possible to synchronize multiple Load Banks for Testing?
    Yes. Multiple Load Banks can be synchronized to test one generator but one Load Bank is not able to test multiple generators at the same time.

     

    6. What is the operating environment for Keypower Load Bank?
    Our Load Banks are to be applied where altitude ≤2500m above sea level,
    ambient temp within -15ºC ~ +55ºC and relative humidity ≤98%.

     

    7. What is the different between Keypower standard load bank and dual voltage?
    For example, a KPLB-500 @400V can test full 500kw @400V, and derating to 165kw only @230V 3 phase. Dual voltage KPLB-500 can test full 500kw @400V and @230V. 

    8. What is generator tester 8961?
    The generator tester 8961 is used for recalling the data from the generators you are testing. Then it can create the test report and sine wave forms. It is good for generator manufacturer and project commissioning.

     

    9. Is the load bank weatherproof?
    Standard type isn't weatherproof, but optional air discharge duct and cam-lock connectors can be fitted on it to enable weatherproof.

     

    10. Does the load bank support remote monitoring and control?
    Standard type doesn't support, but optional programmable Mitsubishi PLC can be fitted to support remote monitoring and control on laptop.

Voltage Versions

 240, 400, 480  VAC

kW Models

1,2,2,5,10, 30, 40, 50, 100, 200, 300, 500, 800 & 1000 kW

Frequency

50/60 Hz

Resolution

1 kW

Configuration

Three Phase, 4 Wire Wye or 3 Wire Delta connection available